Quaere nos
Linguae
ASTM F2063
Nickel-Titanium Figura Memoria Alloys pro Medical machinis et chirurgicis implantatorum
ASTM F2063 norma specificatio est pro forma fabricata Nickel-Titanium Memoria Alloys pro Medical machinis et implantationibus chirurgicis. Tegit chemicam, physicam, mechanicam et metallurgicam requisita ad vectem nickel-titanium, productos planos involutos, et fistulas nominaliter 54.5- ad 57.0-centum nickel continens et adhibita ad fabricam medicam machinarum et implantationem chirurgicam.
Compositio chemica
ATSM F2063-12 Requisita chemica:
| Elementumum | Compositio,% (massa/massa) |
| Nickel | 54.5 ad 57.0 |
| Carbon (Maximum) | 0.050 |
| Cobalt (Maximum) | 0.050 |
| Aeris (Maximum) | 0.010 |
| Chromium (Maximum) | 0.010 |
| Hydrogeniumium (Maximum) | 0.005 |
| Ferrum (Maximum) | 0.050 |
| Niobium (Maximum) | 0.025 |
| Nitrogen plus Oxygen (Maximum) | 0.050 |
| Titanium | Libra |
Analysis tolerantiae
| Element | Tolerantia sub minimo aut maximo limite% (massa/massa) |
| Carbon | 0.002 |
| Cobalt | 0.001 |
| Copper | 0.001 |
| Chromium | 0.001 |
| Hydrogen | 0.0005 |
| Ferrum | 0.01 |
| Nickel | 0.2 sub min; 0,2 super max |
| Niobium | 0.004 |
| Nitrogen | 0.004 |
| Oxygen | 0.004 |
Requisita tolerantia
ATSM F2063-12
| Sicut (°C) | Tolerantia dolor (°C) |
| ≥70 | ± 7 |
| 50 < Ut < 70 | ± 10 |
| ≤-50 | ± 15 |
Mechanica Annealed Properties
ATSM F2063-12
| Diameter Mm(in) | Distrahentes vires MPa, Minimum | Prolongatio in 50,0 mm [1.97 in.] vel 4 D, % Minimum |
| ≤50 (<1.97 in) | 551 (79.9 KSI) | 15 |
| >50(>1.97 in) | 551 (79.9 KSI) | 10 |